A 150,000 Btu furnace feeding ductwork sized for 1000 cfm does not deliver 150,000 Btu to the dwelling. Most likely, the burner kicks out on high limit due to over heating. Which is what it should do if there is not enough air flow. In such a case, this furnace has never produced at full capacity, and its longevity was shortened by the steady over heated condition.
All furnace manufacturers match Btu and cfm output. If the ductwork cannot support the cfm requirement, the furnace will not perform to its potential. When replacing a burned out furnace, match the Btu to the ductwork as best you can.
The smoke pipe, or connector from the combustion chamber to the chimney, must run uphill. Before you purchase a replacement boiler of furnace, make sure the breech on the new unit will be lower than the opening in the chimney.
For warm air furnaces, it is also necessary to match the style of furnace with the ductwork. Furnaces are produced in different configurations for different applications. There are counter flow models with a downward flow, low-boy models and high-boy models with an upward flow, and horizontal models with a sideways flow. Some models also come in front or rear flue arrangements which must also be matched. Make sure you equal or improve the venting of any replaced unit.
Extra precautions, such as canvas or flexible connecters, are needed when installing a direct drive blower in place of a belt drive.