Heating and Cooling Info From Warmair.net
Controls
A relay is one of the most versatile controls at our disposal. It allows
an electric current of one voltage to switch the current on and
off to another device or appliance of a different voltage. The
most common example of a relay exists right at the thermostat
of a central heating or air conditioning system. Low voltage (24
volts) is sent to the thermostat from a transformer. When the
thermostat calls for heating, the 24 volts operates a relay that
sends 120 volts or 240 volts to the furnace, depending on the
type of heating system. In air conditioning systems, the 24 volt
current trips a relay at the air handler to run the blower (which
can be 120 volts or 240 volts) and a relay known as a contactor
on the condenser to provide 240 volts for the compressor and fan.
The device itself is simple in design. Thin copper wire is wound around a
hollow sleeve. Inside the sleeve is a steel rod with electrical
contacts attached to one end. When current is passed through the
windings of copper wire, the sleeve becomes magnetic and pulls
the rod into it. The electrical contacts unite, and current is
transferred to the intended device. Relays are used in motor vehicles,
appliances in the home, and in the work place. The click heard
when a computer connects to a telephone line for the internet
service is a relay engaging.
The fan center relay can be found inside the cabinet of a furnace or air handler.
It has a transformer to reduce the line voltage (120 or 240 volts)
to low voltage and low amperage (24 volts and usually less than
40 milliamps). This reduces the risk of fire or injury from exposure
to live circuits and allows control wiring to be of smaller gauge
and lesser expense to install. The relay will have a switching
capability to make a connection (normally open) and disconnect
a circuit (normally closed). On an oil or gas fired furnace with
central air, the relay will disconnect the burner and engage the
blower and condenser simultaneously if the thermostat calls for
cooling. This prevents the heat from coming on by mistake.
The protecto relay, also known as a burner relay on an oil fired furnace, is
explained in the oil burner section.
In order to use 24 volts to control the condenser for a heat pump or central
air conditioner, a relay known as a contactor is used. The contactor
must be capable of switching a high voltage and high amperage
load on and off. It can have many terminals on it. The crankcase
heater, the condenser fan, and the compressor all tap into the
current available at the contactor. It is constructed of materials
that will allow it to function for years under stressed conditions,
but eventually will need replacing. It is imperative that the
power be disconnected at the main panel and at the service disconnect
outside at the condenser before any access is made to the electrical
connections at the condenser.
Copyright © 1999 Warmair.com, Inc.
Back to Main Page